The samples were purplish red to red in colour and ranged from 1.40 to 2.17 ct.
GIA gemmologists analysed them using conventional microscopy, Fourier-transform infrared (FTIR) spectroscopy, and laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS).
Magnification revealed triangular growth marks, sub-parallel striations, and “heat wave”-like formations at the interface between the overgrowth and the seed. The overgrowth also contained numerous flux inclusions. Characteristics of the natural seeds included healed fractures, heat-altered crystals and intersecting needles.
Three samples were fabricated into wafers for LA-ICP-MS analysis of their trace-element chemistry. For comparison purposes, the authors also collected chemistry data on representative synthetic ruby crystals: one flux-grown Douros and one hydrothermal example.
On the basis of microscopic observation and for convenience, the authors divided the samples into two groups they dubbed “type I” and “type II”. Type I had no discernable boundary between the natural seed and the synthetic overgrowth, which was often confined to the table facet alone. Type II samples had much thicker synthetic overgrowth, with an obvious “dusty” interface between the two.
In the type I sample analysed by LA-ICP-MS, the seed provided trace-element chemistry representative of natural corundum, while the synthetic overgrowth lacked elements such as vanadium, iron and gallium, but had elevated levels of Cr (up to 6,784 ppma), along with heavy elements atypical for natural corundum, including molybdenum, rhodium and the heavy metal platinum.
The type II sample analysed had even higher Cr levels in the synthetic overgrowth (up to 10,353 ppma), but unlike the type I example it also contained elements found in natural corundum, including magnesium, titanium, vanadium, iron and gallium. However, manganese, nickel, zinc and platinum were also present. This indicates different growth conditions from the type I example above. The natural seed had trace-element chemistry very similar to the type I sample described.
In both samples, the synthetic overgrowth did not correlate with the as-grown hydrothermal (Russian) and flux-grown (Douros) synthetic rubies included as comparisons.